Chilled Mirror Dew Point Hygrometer
Zoom Browse
Product Name: Chilled Mirror Dew Point Hygrometer
Product Numbers: DP29
Product Specifications: Accuracy:≤±0.2°C,±1Digit
Product Remark: easurement Principle:Chilled Mirror
Product Class:Measuring and Testing Instruments > Temperature Measuring Instrument > Dew Point Meter
Product Details
【DateTime:2018-03-13 Browse:】【Font: Big Mid Small】【Print】【Close

Chilled Mirror Dew Point Hygrometer

       Multifunctional, portable dew point humidity meter , especially designed for field use. Typically apply to dew point measurement of SF6gas.

Features: 

* Based on the principle of chilled mirror. 
* Accurate measurement is guaranteed. 
* The system is stable, No need to repeatedly calibrated. 
* A built in electronic sample gas flow monitor. 
* Use RS-232 data output to connect with PC.

Specification: 

DP29-40 is specifically designed for air dew point measurement. It is applicable to standard reference for electronic component durability , dew point control for firing furnaces, dew point control for fuel cell test system, etc.
DP29-SF6 is specially for the measurement of Sulfur Hexafluoride (SF6). 
DP29-60 is a standard type. It applies to standard reference for laboratory calibration, moisture control for ceramic firing furnaces, humidity control for thermo-hygrostat chamber. 

Model DP29-40 DP29-60 DP29-SF6 DP29-70
Range Under 0ºC -40ºC -60ºC -60ºC -70ºC
Under 10ºC -40ºC -60ºC -60ºC -65ºC
Under 20ºC -35ºC -55ºC -55ºC -60ºC
Under 35ºC -30ºC -45ºC -45ºC -50ºC
Accuracy <<±0.2ºC,±1Digit
Repeatability <<±0.1ºC,±1Digit
Resolution 0.1ºC
Defaulit Output USB
Optional Output ±10mv/ºC(0ºC=0mv)or 4-20mA
Measurnment Principle Chilled Mirror
Refrigeration Semiconductor Refrigeration
Inlet Flow 15~60L/h,Generally 30~40L/h
Inlet Pressure 10mbar~10bar(1kpa~1Mpa)
Response Time 2ºC/Second(Maximum)
Voltage 220V AC±10%   50/60HZ
Pump Optional Accessory
Mirror Check

Press the Conversion Key to mirror check mode(‘CH’ on the display),and

check manually

Instrument Check Press the Test Cooling Key,open the measurment probe,and check manually at mirror check mode
Consumption About 160 Watts
Temperature 0~50ºC
Humidity <90%,No Condensation
Dimension 342(W)x140(H)X326(D) mm
Weight About 7.22kg
Standard accessories Main Unit
Inlet Tube(FEP,3m),With Connector
Instruction Manual
Packaging Box
Optional Accessories RS-232C Data Cable with Software

*Accuracy:≤±0.2°C,±1Digit 
*Repeatability:≤±0.1°C,±1Digit 
*Resolution:0.1°C 
*Default Output:USB 
*Optional Output:±10mv/°C (0°C= 0mv) or 4-20mA 
*Measurement Principle:Chilled Mirror 
*Refrigeration:Semiconductor Refrigeration 
*Inlet Flow:15~60L/h, Generally 30~40L/h 
*Inlet Pressure:10mbar~10bar (1kpa~1Mpa) 
*Response Time:2°C/Second (Maximum) 
*Pump:Optional Accessory 
*Mirror Check:Press the Mode Conversion Key to mirror check mode (‘CH’ on the display), and check manually 
*Instrument Check Press the Test Cooling Key, open the measurement probe, and check manually at mirror check mode. 
*Voltage:220VAC±10%,50/60HZ 
*Consumption:About 160 Watts 
*Temperature:0~50°C 
*Humidity:<90% , No Condensation 
*Weight:About 7.22kg 
*Dimension:342(W)x140(H)x326(D) mm 

Standard Accessories: 
1. Main Unit 
2. Inlet Tube (FEP,3m), With Connector 
3. Instruction Manual 
4. Packaging Box 

Optional Accessories: 
1. USB, RS-232 data cable with software