Chilled Mirror Dew Point Hygrometer
Multifunctional, portable dew point humidity meter , especially designed for field use. Typically apply to dew point measurement of SF6gas.
Features:
* Based on the principle of chilled mirror.
* Accurate measurement is guaranteed.
* The system is stable, No need to repeatedly calibrated.
* A built in electronic sample gas flow monitor.
* Use RS-232 data output to connect with PC.
Specification:
DP29-40 is specifically designed for air dew point measurement. It is applicable to standard reference for electronic component durability , dew point control for firing furnaces, dew point control for fuel cell test system, etc.
DP29-SF6 is specially for the measurement of Sulfur Hexafluoride (SF6).
DP29-60 is a standard type. It applies to standard reference for laboratory calibration, moisture control for ceramic firing furnaces, humidity control for thermo-hygrostat chamber.
Model |
DP29-40 |
DP29-60 |
DP29-SF6 |
DP29-70 |
Range |
Under 0ºC |
-40ºC |
-60ºC |
-60ºC |
-70ºC |
Under 10ºC |
-40ºC |
-60ºC |
-60ºC |
-65ºC |
Under 20ºC |
-35ºC |
-55ºC |
-55ºC |
-60ºC |
Under 35ºC |
-30ºC |
-45ºC |
-45ºC |
-50ºC |
Accuracy |
<<±0.2ºC,±1Digit |
Repeatability |
<<±0.1ºC,±1Digit |
Resolution |
0.1ºC |
Defaulit Output |
USB |
Optional Output |
±10mv/ºC(0ºC=0mv)or 4-20mA |
Measurnment Principle |
Chilled Mirror |
Refrigeration |
Semiconductor Refrigeration |
Inlet Flow |
15~60L/h,Generally 30~40L/h |
Inlet Pressure |
10mbar~10bar(1kpa~1Mpa) |
Response Time |
2ºC/Second(Maximum) |
Voltage |
220V AC±10% 50/60HZ |
Pump |
Optional Accessory |
Mirror Check |
Press the Conversion Key to mirror check mode(‘CH’ on the display),and
check manually
|
Instrument Check |
Press the Test Cooling Key,open the measurment probe,and check manually at mirror check mode |
Consumption |
About 160 Watts |
Temperature |
0~50ºC |
Humidity |
<90%,No Condensation |
Dimension |
342(W)x140(H)X326(D) mm |
Weight |
About 7.22kg |
Standard accessories |
Main Unit |
Inlet Tube(FEP,3m),With Connector |
Instruction Manual |
Packaging Box |
Optional Accessories |
RS-232C Data Cable with Software |
*Accuracy:≤±0.2°C,±1Digit
*Repeatability:≤±0.1°C,±1Digit
*Resolution:0.1°C
*Default Output:USB
*Optional Output:±10mv/°C (0°C= 0mv) or 4-20mA
*Measurement Principle:Chilled Mirror
*Refrigeration:Semiconductor Refrigeration
*Inlet Flow:15~60L/h, Generally 30~40L/h
*Inlet Pressure:10mbar~10bar (1kpa~1Mpa)
*Response Time:2°C/Second (Maximum)
*Pump:Optional Accessory
*Mirror Check:Press the Mode Conversion Key to mirror check mode (‘CH’ on the display), and check manually
*Instrument Check Press the Test Cooling Key, open the measurement probe, and check manually at mirror check mode.
*Voltage:220VAC±10%,50/60HZ
*Consumption:About 160 Watts
*Temperature:0~50°C
*Humidity:<90% , No Condensation
*Weight:About 7.22kg
*Dimension:342(W)x140(H)x326(D) mm
Standard Accessories:
1. Main Unit
2. Inlet Tube (FEP,3m), With Connector
3. Instruction Manual
4. Packaging Box
Optional Accessories:
1. USB, RS-232 data cable with software