Specifications
Several types transducer for selection, measuring pipe size from DN15mm to DN6000mm
Main Features:
features |
description |
High Accuracy
measuring |
Linearity: better than 0.5%, Repeatability: better than 0.2%, Accuracy: better than ±1% |
Wide measuring range |
Several types transducer for selection, measuring pipe size from DN15mm to DN6000mm |
Chinese & English
menu |
Different version can support Chinese or English display, easy to operate. |
High Reliability |
Adopt low voltage, multi-pulse technology to improve accuracy, useful life and reliability. |
Strong
Anti-interference |
Dual-balance signal differential receiver/driver circuit to avoid
interference of converter, TV tower, high voltage line etc. |
Powerful Recording
Function |
Automatically record the following data:
1. The totalizer data of the last 512 days/128 months/10 years
2. The time and corresponding flow meter of the last 64 times of
power on and off events |
General Specification:
Power Supply |
DC8-36V or AC85-264V |
Input |
3 channel 4-20mA analog input |
Output |
Isolation RS-485 output, 2 channel isolation OCT output: 1 channel
isolation 4-20mA output (two-wire system) |
Communication
Protocols |
Compatible with METER-BUS, MODBUS, Fuji extended protocol and
general water meter protocol |