Are Loading Data, Please wait while loading...

Hand Tools and Hardware Tools | Machinery and Engineering Tools | Measuring and Testing Instruments | Measuring Tools

Product Search
  •   
Product Columns
  Home >> Products >> Measuring and Testing Instruments >> Survey And Construction Instruments >> Rebar Corrosion Detector >> Display
Rebar Corrosion Detector&Rebar Locator Concrete Covermeter
Zoom Browse
Product Name: Rebar Corrosion Detector&Rebar Locator Concrete Covermeter
Product Numbers: RELO-1350
Product Specifications: Range: Φ6 – Φ50 rebar
Product Unit: Measuring Potential:±2000mV
Product Class:Measuring and Testing Instruments > Survey And Construction Instruments > Rebar Corrosion Detector
Product Details
【DateTime:2014-10-22 Browse:】【Font: Big Mid Small】【Print】【Close
Rebar Corrosion Detector&Rebar Locator Concrete Covermeter
Features:
Integrate the functions of rebar position test , concrete thickness test, rebar diameter test and rebar corrosion degree test into one product.
What Used for:
--Testing concrete cover thickness
--Test concrete member internal reinforcement position, rebar spacing, reinforcement position distribution.
--Estimation bar diameter
--Detection of Cable and Plumbing pipe
--Detection of steel corrosion extent
 
Specification of Rebar locator
Bar diameter application range(mm) Φ6 – Φ50
maximum value permissible error of Bar diameter ≤±1
Protective layer thickness measuring range  
The first measuring range (mm) 6 - 90
The second measuring range (mm) 7-180
The maximum error of reinforced protective layer thickness test value  
The first measuring range (mm) The second measuring range (mm)  
6 - 59 7 - 79 ≤±1
60 - 69 80 - 119 ≤±2
70 -90 120 - 180 ≤±4
Work temperature  -50
relative humidity RH < 90%
power supply mode Alkaline cell X 6
 
Specification of Rebar corrosion system
Measuring Potential ±2000mV
Test accuracy ± 1mV
Measuring Space 1-99 cm (adjustable)
Ambient Temperature -10℃~+40
Environment Requirement to avoid direct exposure to the sun for a long time.
Relative Humidity <90%RH
Electromagnetic Interference no strong alternating electromagnetic field
【Font: Big Mid Small】【Print】【Close】【Back to Top