Rebar Locator & Concrete Cover Meter is an portable, quick and easy-to-use instrument for inspecting reinforcing bars in concrete. The Rebar Locator generates a magnetic field and measures any change induced by presence of the magnetic material. The magnitude of this change is indicated on the instrument meter, which has been calibrated to read directly in diameter and depth of the bar.
The use of the instrument is not restricted to inspecting reinforcing bars, but any magnetic material and ferromagnetic objects.
Applications
Determine the location, depth, diameter and orientation of tendons in prestressed concrete.
Measure the concrete cover.
Detect location of tendon splices and broken ends, etc. in prestressed concrete.
Detect the location of pipes conduit, flues, ducts, and manhole covers and any other ferromagnetic objects.
Specifications
Uni-Probe with Two Detect Range: The Uni-probe has both a small and large detect range.
Detect Closely Located Bars: Can detect closely situated, parallel bars with 1.5 diameter gap.
Unlimited Cyberscan(picture 1): Can scan object with unlimited size, and display the thickness of cover concrete and bars distributing simultaneously.
Actual Distributing Map of Bars(picture 2): Can output the actual distributing map of bars after several times scanning.
Transverse Section Bars Distributing Map: Can output the transverse section map of bars distributing.
Detection of Rebar Diameter Range: 6mm to 32mm(0.24in~1.26in)
The detected rebar diameter range is depends on the depth of the rebar.
Diameter Φ(mm)
|
6
|
8
|
10
|
12
|
14
|
16
|
18
|
20
|
22
|
25
|
28
|
32
|
36
|
40
|
50
|
Depth(mm)
|
SmallRang
|
min
|
8
|
6
|
8
|
8
|
9
|
9
|
10
|
10
|
10
|
10
|
10
|
12
|
12
|
14
|
16
|
max
|
72
|
76
|
80
|
82
|
84
|
84
|
86
|
86
|
86
|
90
|
90
|
90
|
90
|
90
|
90
|
LargeRang
|
Min
|
8
|
10
|
12
|
13
|
14
|
15
|
16
|
18
|
18
|
18
|
20
|
22
|
24
|
26
|
28
|
max
|
100
|
118
|
126
|
130
|
144
|
146
|
148
|
160
|
162
|
162
|
172
|
180
|
180
|
180
|
180
|
Detection of Thickness Range of Cover Concrete: 10mm to 130mm(0.39in~5.12in)
Depends on the Rebar Diameter.
Diameter Φ(mm)
|
6
|
8
|
10
|
12
|
14
|
16
|
18
|
20
|
22
|
25
|
28
|
32
|
Thickness(mm)
|
min
|
8
|
12
|
12
|
14
|
14
|
16
|
16
|
18
|
18
|
20
|
22
|
22
|
max
|
60
|
62
|
66
|
68
|
68
|
72
|
72
|
74
|
74
|
76
|
76
|
80
|
Accuracy of Cover Thickness:
Depends on the cover thickness.
Cover Thickness(mm)
|
Small Range
|
6~59
|
60~69
|
70~90
|
Larger Range
|
8~79
|
80~119
|
120~180
|
Accuracy(mm)
|
±1
|
±2
|
±4
|